radioisotope

  • IMAGING PLATES

       
         
     
    MS - General

    The BAS-MS, like all Imaging Plates, has a flexible polyester base coated with highly dispersed barium fluorohalide phosphor crystals (BaF(Br,I):Eu2+).

    When a radioactively labeled sample is exposed to an IP, the energy from that sample is transferred to the phosphor crystals, and stored as trapped electrons. In short, the electrons become trapped to form 'F-centers' in the BaF(Br,I) matrix.

    Scanning the exposed IP with a He-Ne laser (633nm) releases the trapped electrons and photons at about 400nm. This process is known
    as photo-stimulated luminescence. The blue light emitted is collected to produce the digitized image.

    MS Imaging Plate 20x25 cm
    MS Imaging Plate 23x25 cm
    MS Imaging Plate 23x25 cm
    MS Imaging Plate 23x40 cm
    MS Imaging Plate 35x43 cm

       

     

     
    TR - Tritium

    TR Imaging Plate 20x25 cm - Sensitive to tritium. For BAS 5000, FLA 3000, 5000, 5100
    TR Imaging Plate 20x40 cm - Sensitive to tritium. For BAS 2000, 2500, FLA 3000, 5000, 5100

         
     
    SR - Hi res.

    These IPs are designed for optimum resolution and durability with wet samples. They are sensitive to all common beta and gamma emitters except 3H.

    SR Imaging Plate 20x25 cm
    SR Imaging Plate 20x40 cm

         
     
    ND -Neutron

    BAS-ND IP is the most accurate Imaging Plate for research using neutrons. The task of capturing and analyzing data from neutron crystallography, neutron radiology and monitoring has become much easier and accurate.

     

     

     

    More about Imaging Plates »

  • IMAGING PLATES (2)

       
         
     
    MS - General

    The BAS-MS, like all Imaging Plates, has a flexible polyester base coated with highly dispersed barium fluorohalide phosphor crystals (BaF(Br,I):Eu2+).

    When a radioactively labeled sample is exposed to an IP, the energy from that sample is transferred to the phosphor crystals, and stored as trapped electrons. In short, the electrons become trapped to form 'F-centers' in the BaF(Br,I) matrix.

    Scanning the exposed IP with a He-Ne laser (633nm) releases the trapped electrons and photons at about 400nm. This process is known
    as photo-stimulated luminescence. The blue light emitted is collected to produce the digitized image.

    MS Imaging Plate 20x25 cm
    MS Imaging Plate 23x25 cm
    MS Imaging Plate 23x25 cm
    MS Imaging Plate 23x40 cm
    MS Imaging Plate 35x43 cm

       

     

     
    TR - Tritium

    TR Imaging Plate 20x25 cm - Sensitive to tritium. For BAS 5000, FLA 3000, 5000, 5100
    TR Imaging Plate 20x40 cm - Sensitive to tritium. For BAS 2000, 2500, FLA 3000, 5000, 5100

         
     
    SR - Hi res.

    These IPs are designed for optimum resolution and durability with wet samples. They are sensitive to all common beta and gamma emitters except 3H.

    SR Imaging Plate 20x25 cm
    SR Imaging Plate 20x40 cm

         
     
    ND -Neutron

    BAS-ND IP is the most accurate Imaging Plate for research using neutrons. The task of capturing and analyzing data from neutron crystallography, neutron radiology and monitoring has become much easier and accurate.

     

     

     